Rheology of PDMS Korasilon fluids M used at the Laboratory for Experimental Tectonics at GFZ Helmholtz Centre for Geosciences, Potsdam, Germany

Description: This dataset provides rheometric data of PDMS Korasilon® Fluids M used for analogue modelling at the Laboratory for Experimental Tectonics at GFZ Helmholtz Centre for Geosciences, Potsdam, Germany. The material samples have been analyzed at the Laboratory for Experimental Tectonics at GFZ Helmholtz Centre for Geosciences, Potsdam (HelTec) using an Anton Paar Physica MCR 301 rheometer in a plate-plate configuration at room temperature (21˚C). Rotational (controlled shear rate) tests with shear rates varying from 10-4 to 1 s-1 were performed. According to our rheometric analysis, the material is Newtonian (n = 1) at strain rates below 1 s-1. The viscosities range from 10 to 2000 Pa s.

Global identifier:

Doi(
    "10.5880/GFZ.FPXO.2025.003",
)

Types:

Origins: /Wissenschaft/GFZ Data Services

Tags: Daten ? Viskosität ? Modellierung ? Geowissenschaften ? EARTH SCIENCE > SOLID EARTH > TECTONICS ? EPOS TCS Multiscale Laboratories ? Rheometer ? Silicon/Silly putty/PDMS ? Stress exponent ?