API src

FP1-ENNONUC 3C, Development of a new type of heat transformer and the investigation of the heat transformer-absorption water pump system combination unit

Description: Objective/Aim: The aim of the project is to develop a new type of heat transformer operating with new agents and attaining considerably higher useful temperatures than the water-libr-heat transformer used at present (c. 150 c). It should also make possible a larger difference between waste heat and useful heat (up to now 40 to 50 k). The performance of this heat transformer will be monitored over a 9-month test period. At the same time a high-temperature absorption heat pump will be developed and tested. Then the two apparatuses will be combined to form a single unit, whose performance will be investigated extensively, with particular emphasis on its control action. General information/description: using the experience gained with the water-libr-heat transformer, a new type of heat transformer is to be developed based on more suitable agent systems. Rough calculations have already been carried out suggesting the following data for the heat transformer: evaporator temperature: 100 c; expeller final temperature: 100 c; condensation temperature: 38 c; absorption final temperature: 172 c; useful output: 20kw; input: 50kw. These calculations were based on use of the agents trifluoroethanol (tfe) and tetraethylene glycol dimethyl ether; experience having been gained with these on a small experimental unit, they were chosen for both the above calculations and for later operation of the system. It is planned at a later stage to switch to other agents permitting absorption final temperatures of nearly 200 c to be attained. Likely candidates are: tfe - n-methyl pyrrolidone; tfe - pyrrolidone; tfe - isoquinoline and perhaps also: perfluoropropionic acid (pfpa)-dtg.

Types:
SupportProgram

Tags: Abwärmenutzung ? Absorption ? Abwärme ? Temperatur ? Wärmepumpe ? Nutzenergie ? Wasser ? Daten ? Effizienzsteigerung ? Energiesparsystem ? Temperaturerhöhung ? Wärmetransformator ?

Region: Nordrhein-Westfalen Nordrhein-Westfalen

Bounding boxes: 5.8663153° .. 9.4617417° x 50.3226897° .. 52.531493499999996° 5.8662503507406045° .. 9.461478369136085° x 50.323011952581965° .. 52.53144342795586°

License: Creative Commons Namensnennung-keine Bearbeitung-Nichtkommerziell 4.0

Language: Englisch/English

Organisations

Last harvest: 07.09.2026 00:28

Time ranges: 1986-04-01 - 1988-12-31

Status

Quality score

Accessed 1 times.