API src

Found 5348 results.

Similar terms

s/cad/Cd/gi

Other language confidence: 0.7709267670465684

Physical oceanography during RV HEINCKE cruise HE645

Conductivity-temperature-depth profiles were measured using a Seabird SBE 911plus CTD during RV HEINCKE cruise HE645. The CTD was equipped with duplicate sensors for temperature (SBE3plus), conductivity (SBE4) and oxygen (SBE43). Additional sensors such as a WET Labs C-Star transmissometer, a WET Labs ECO-AFL fluorometer and an altimeter (PSA-916 Teledyne (Benthos)) were mounted to the CTD. Temperature, conductivity and oxygen sensors are calibrated by the manufacturer once a year before being mounted in January. They are used throughout the year and no post-cruise or in-situ calibration is applied. All other sensors are calibrated irregularly. Data were connected to the station book of the specific cruise as available in the DSHIP database. Processing of the data including removal of obvious outliers followed the procedures described in CTD Processing Logbook of RV HEINCKE (hdl:10013/epic.47427). The processing report for this dataset is linked below.

Hintergrundwerte von anorganischen Stoffen in Böden in Deutschland 1:1.000.000 (WMS)

Web Map Service (WMS) zur Karte der Hintergrundwerte von anorganischen Stoffen in Böden in Deutschland. Durch die LABO wurden 2017 für 16 Elemente neue, bundesweite Hintergrundwerte veröffentlicht. Sie beruhen auf Profilinformationen und Messdaten von Königswasserauszügen, die durch die BGR zusammengeführt und homogenisiert wurden. Daten mit hohen Bestimmungsgrenzen wurden nach bestimmten Kriterien von der weiteren Auswertung ausgeschlossen, damit die Bestimmungsgrenzen nicht die Hintergrundwerte beeinflussen. Um die Hintergrundwerte nicht durch Regionen mit hoher Stichprobendichte überproportional beeinflussen zu lassen, wurde in Teilen eine räumliche Ausdünnung durchgeführt. Die Werte mehrerer Horizonte eines Standortes wurden durch tiefengewichtete Mittelwerte zu einem Wert zusammengezogen. Zur Auswertung wurden die vorhandenen Messwerte verschiedenen Gruppen von Bodenausgangsgesteinen zugeordnet. Zudem wurde unterschieden, ob die Proben im Oberboden, im Unterboden oder im Untergrund genommen wurden. Bei den Oberböden wurde bei der Auswertung auch die unterschiedliche Nutzung (Acker, Grünland, Forst) berücksichtigt. Lockergesteine wurden aufgrund ihrer unterschiedlichen Zusammensetzung getrennt nach Nord- und Süddeutschland ausgewertet. Durch die Aufteilung der Daten in Teilkollektive wurden nicht in allen Fällen verlässliche Fallzahlen erreicht, sodass nur Hintergrundwerte mit Fallzahlen ?20 dargestellt werden. Das genaue Vorgehen bei der Ableitung ist dem Bericht der LABO-Bund/Länder-Arbeitsgemeinschaft Bodenschutz (2017): 'Hintergrundwerte für anorganische und organische Stoffe in Böden', 4. überarbeitete und ergänzte Auflage, zu entnehmen.

Physical oceanography during HEINCKE cruise HE543

Grundwassermessstelle DEGM_DENW_073506813: KLETT 431

Stammdaten und Analysedaten zu den Grundwassermessstellen im EUA-Messnetz: Messtelle DEGM_DENW_073506813 (KLETT 431)

Physical oceanography during RV HEINCKE cruise HE615

Conductivity-temperature-depth profiles were measured using a Seabird SBE 911plus CTD during RV HEINCKE cruise HE615. The CTD was equipped with duplicate sensors for temperature (SBE3plus), conductivity (SBE4) and oxygen (SBE43). Additional sensors such as a WET Labs C-Star transmissometer, a WET Labs ECO-AFL fluorometer and an altimeter (PSA-916 Teledyne (Benthos)) were mounted to the CTD. Temperature, conductivity and oxygen sensors are calibrated by the manufacturer once a year before being mounted in January. They are used throughout the year and no post-cruise or in-situ calibration is applied. All other sensors are calibrated irregularly. Data were connected to the station book of the specific cruise as available in the DSHIP database. Processing of the data including removal of obvious outliers followed the procedures described in CTD Processing Logbook of RV HEINCKE (hdl:10013/epic.47427). The processing report for this dataset is linked below.

WMS MSRL: D8-Schadstoffe (sh-llur), Mittelwert 2005-2010

Der WMS umfasst Schadstoffe im Wasser und im Sediment, die an Messstationen des LLUR erfasst werden. Parameter: Quecksilber, Blei, Kupfer, Nickel, Arsen, Cadmium, Chrom, Zink.

Raw data of physical oceanography during RV HEINCKE cruise HE658

Raw physical oceanography data was acquired by a ship-based Seabird SBE911plus CTD-Rosette system onboard RV HEINCKE. The CTD was equipped with duplicate sensors for temperature (SBE3plus), conductivity (SBE4) and oxygen (SBE43). Additional sensors such as a WET Labs C-Star transmissometer, a WET Labs ECO-AFL fluorometer (FLRTD) and an altimeter (Teledyne Benthos PSA-916) were mounted to the CTD. The data was recorded using pre-cruise calibration coefficients. No correction, post-cruise calibration or quality control was applied. Processed profile data are available via the link below (Other version).

Raw data of physical oceanography during RV HEINCKE cruise HE659

Raw physical oceanography data was acquired by a ship-based Seabird SBE911plus CTD-Rosette system onboard RV HEINCKE. The CTD was equipped with duplicate sensors for temperature (SBE3plus), conductivity (SBE4) and oxygen (SBE43). Additional sensors such as a WET Labs C-Star transmissometer, a WET Labs ECO-AFL fluorometer (FLRTD) and an altimeter (Teledyne Benthos PSA-916) were mounted to the CTD. The data was recorded using pre-cruise calibration coefficients. No correction, post-cruise calibration or quality control was applied. Processed profile data are available via the link below (Other version).

CTD-Messketten-Station WWS 2

Messkette mit CTD-Messung (Salzgehalt, Temperatur, Wasserstand, Trübung). Zwei Zeitreihen mit Delta t = 5 Minuten. Es wurde auf den Tiefen 3 m, 7 m, 12 m und 22 m gemessen (NHN). Hinweis zum Messintervall dt: Die CTD-Messungen wurden in dem angebenen Messintervall als Momentanmessung ausgeführt. Eine Momentanmessung besteht hierbei aus 20 Einzelmessungen mit 4 Hz (0,25 s). Konkret: alle 5 Minuten wurde für 5 s mit 4 Hz gemessen und als Mittelwert abgespeichert.

Physicochemical soil property data for archive samples of the Saxon agricultural soil monitoring program

The continuous agricultural soil monitoring program (BDF) by the Saxon State Office for Environment, Agriculture, and Geology (LfULG) is operational since 1995, collecting and analysing samples periodically from 60 monitoring sites across Saxony, Germany. This dataset provides physicochemical soil property data for 920 archive samples available from the Saxon soil information system FIS Boden, including soil organic carbon, total nitrogen, various total and extractable elemental contents, soil pH, cation exchange capacity, and particle size distribution. Additional soil physical data (bulk density, soil water retention) have been merged from undisturbed sample data, resulting in a total of 123 variables, though with varying availability. This dataset provides the majority of reference data for the mid-infrared soil spectral library for agricultural soils in Saxony, Germany.

1 2 3 4 5 … 533 534 535