API src

Found 41 results.

GTS Bulletin: IUXD34 EDZW - Observational data (Binary coded) - BUFR (details are described in the abstract)

The IUXD34 TTAAii Data Designators decode as: T1 (I): Observational data (Binary coded) - BUFR T1T2 (IU): Upper air T1T2A1 (IUX): Other upper air reports A2 (D): 90°E - 0° northern hemisphere(The bulletin collects reports from stations: 10393;Lindenberg;) (Remarks from Volume-C: High resolution 2 sec., BUFR309057, Level 300) IUXD34 BUFR bulletin available 10393 Lindenberg from EDZW (Deutscher Wetterdienst) up to 300 hPa at 00 UTC, 06 UTC, 12 UTC, 18 UTC

GTS Bulletin: IUSD24 EDZW - Observational data (Binary coded) - BUFR (details are described in the abstract)

The IUSD24 TTAAii Data Designators decode as: T1 (I): Observational data (Binary coded) - BUFR T1T2 (IU): Upper air T1T2A1 (IUS): Radio soundings from fixed land stations (entire sounding) A2 (D): 90°E - 0° northern hemisphere(The bulletin collects reports from stations: 10393;Lindenberg;) (Remarks from Volume-C: High resolution 2 sec., BUFR309057) IUSD24 BUFR bulletin available 10393 Lindenberg from EDZW (Deutscher Wetterdienst) at 00 UTC, 06 UTC, 12 UTC, 18 UTC

GTS Bulletin: IUKD04 EDZW - Observational data (Binary coded) - BUFR (details are described in the abstract)

The IUKD04 TTAAii Data Designators decode as: T1 (I): Observational data (Binary coded) - BUFR T1T2 (IU): Upper air T1T2A1 (IUK): Radio soundings from fixed land stations (up to 100 hPa) A2 (D): 90°E - 0° northern hemisphere(The bulletin collects reports from stations: 10393;Lindenberg;) (Remarks from Volume-C: high resolution 2 sec.)

GTS Bulletin: ISCD01 EDZW - Observational data (Binary coded) - BUFR (details are described in the abstract)

The ISCD01 TTAAii Data Designators decode as: T1 (I): Observational data (Binary coded) - BUFR T1T2 (IS): Surface/sea level T1T2A1 (ISC): Climatic observations from land stations A2 (D): 90°E - 0° northern hemisphere (The bulletin collects reports from stations: 10015;Helgoland;10020;List auf Sylt;10035;Schleswig;10055;Fehmarn;10147;Hamburg-Fuhlsbüttel;10162;Schwerin;10184;Greifswald;10200;Emden;10224;Bremen;10270;Neuruppin;10338;Hannover;10361;Magdeburg;10393;Lindenberg;10400;Düsseldorf;10469;Leipzig/Halle;10488;Dresden-Klotzsche;10506;Nürburg-Barweiler;10548;Meiningen;10637;Frankfurt/Main;10685;Hof;10738;Stuttgart-Echterdingen;10763;Nürnberg;10788;Straubing;10852;Augsburg;10946;Kempten;)

GTS Bulletin: ISID01 EDZW - Observational data (Binary coded) - BUFR (details are described in the abstract)

The ISID01 TTAAii Data Designators decode as: T1 (I): Observational data (Binary coded) - BUFR T1T2 (IS): Surface/sea level T1T2A1 (ISI): Intermediate synoptic observations from fixed land stations A2 (D): 90°E - 0° northern hemisphere (The bulletin collects reports from stations: 10004;UFS TW Ems;10015;Helgoland;10020;List auf Sylt;10035;Schleswig;10055;Fehmarn;10147;Hamburg-Fuhlsbüttel;10162;Schwerin;10184;Greifswald;10200;Emden;10224;Bremen;10270;Neuruppin;10338;Hannover;10361;Magdeburg;10393;Lindenberg;10400;Düsseldorf;10469;Leipzig/Halle;10488;Dresden-Klotzsche;10506;Nürburg-Barweiler;10548;Meiningen;10637;Frankfurt/Main;10685;Hof;10738;Stuttgart-Echterdingen;10763;Nürnberg;10788;Straubing;10852;Augsburg;10946;Kempten;) (Remarks from Volume-C: SYNOP)

GRUAN RS92 Product (beta)

First GRUAN product (beta)

GTS Bulletin: IUXD54 EDZW - Observational data (Binary coded) - BUFR (details are described in the abstract)

The IUXD54 TTAAii Data Designators decode as: T1 (I): Observational data (Binary coded) - BUFR T1T2 (IU): Upper air T1T2A1 (IUX): Other upper air reports A2 (D): 90°E - 0° northern hemisphere(The bulletin collects reports from stations: 10393;Lindenberg;) (Remarks from Volume-C: High resolution 2 sec., BUFR309057, Level 500) IUXD54 BUFR bulletin available 10393 Lindenberg from EDZW (Deutscher Wetterdienst) up to 500 hPa at 00 UTC, 06 UTC, 12 UTC, 18 UTC

GTS Bulletin: IUKD24 EDZW - Observational data (Binary coded) - BUFR (details are described in the abstract)

The IUKD24 TTAAii Data Designators decode as: T1 (I): Observational data (Binary coded) - BUFR T1T2 (IU): Upper air T1T2A1 (IUK): Radio soundings from fixed land stations (up to 100 hPa) A2 (D): 90°E - 0° northern hemisphere(The bulletin collects reports from stations: 10393;Lindenberg;) (Remarks from Volume-C: High resolution 2 sec., BUFR309057) IUKD24 BUFR bulletin available 10393 Lindenberg from EDZW (Deutscher Wetterdienst) up to 100 hPa at 00 UTC, 06 UTC, 12 UTC, 18 UTC

RS92 GRUAN Data Product

This product is based on Vaisala RS92 radiosonde measurements of temperature, humidity, wind and pressure that have been processed following the requirements of the GCOS Reference Upper Air Network (GRUAN) that were described in Immler et al. [2010]. The GRUAN data product file comply to the requirements of GRUAN in particular by providing a full uncertainty analysis. The uncertainty is calculated according to the recommendations of the “Guide for expressing uncertainty in measurement” [GUM2008]. The total uncertainty is assessed from estimates of the calibration uncertainty, the uncertainty of corrections and statistical standard deviations. Corrections are applied such that the data is bias free according to current knowledge.

RS92 GRUAN Data Product (beta)

This product is based on Vaisala RS92 radiosonde measurements of temperature, humidity, wind and pressure that have been processed following the requirements of the GCOS Reference Upper Air Network (GRUAN) that were described in Immler et al. [2010]. The GRUAN data product file comply to the requirements of GRUAN in particular by providing a full uncertainty analysis. The uncertainty is calculated according to the recommendations of the “Guide for expressing uncertainty in measurement” [GUM2008]. The total uncertainty is assessed from estimates of the calibration uncertainty, the uncertainty of corrections and statistical standard deviations. Corrections are applied such that the data is bias free according to current knowledge.

1 2 3 4 5