API src

Found 1735 results.

Physical oceanography during RV HEINCKE cruise HE645

Conductivity-temperature-depth profiles were measured using a Seabird SBE 911plus CTD during RV HEINCKE cruise HE645. The CTD was equipped with duplicate sensors for temperature (SBE3plus), conductivity (SBE4) and oxygen (SBE43). Additional sensors such as a WET Labs C-Star transmissometer, a WET Labs ECO-AFL fluorometer and an altimeter (PSA-916 Teledyne (Benthos)) were mounted to the CTD. Temperature, conductivity and oxygen sensors are calibrated by the manufacturer once a year before being mounted in January. They are used throughout the year and no post-cruise or in-situ calibration is applied. All other sensors are calibrated irregularly. Data were connected to the station book of the specific cruise as available in the DSHIP database. Processing of the data including removal of obvious outliers followed the procedures described in CTD Processing Logbook of RV HEINCKE (hdl:10013/epic.47427). The processing report for this dataset is linked below.

Physical oceanography during RV HEINCKE cruise HE615

Conductivity-temperature-depth profiles were measured using a Seabird SBE 911plus CTD during RV HEINCKE cruise HE615. The CTD was equipped with duplicate sensors for temperature (SBE3plus), conductivity (SBE4) and oxygen (SBE43). Additional sensors such as a WET Labs C-Star transmissometer, a WET Labs ECO-AFL fluorometer and an altimeter (PSA-916 Teledyne (Benthos)) were mounted to the CTD. Temperature, conductivity and oxygen sensors are calibrated by the manufacturer once a year before being mounted in January. They are used throughout the year and no post-cruise or in-situ calibration is applied. All other sensors are calibrated irregularly. Data were connected to the station book of the specific cruise as available in the DSHIP database. Processing of the data including removal of obvious outliers followed the procedures described in CTD Processing Logbook of RV HEINCKE (hdl:10013/epic.47427). The processing report for this dataset is linked below.

Continuous thermosalinograph oceanography along RV SONNE cruise track SO285

Underway temperature and salinity data was collected along the cruise track with two autonomous measurement systems, called self-cleaning monitoring boxes (SMBs). Usually, the SMBs are changed after 12 hours. While temperature is taken at the water inlet in about 4 m depth, salinity is estimated within the SMB from conductivity and interior temperature. Salinity was calibrated for each box independently against discrete water samples (see additional attachment). No temperature calibration was performed. For details to all processing steps see Data Processing Report.

Physical oceanography during ALKOR cruise AL639

Conductivity-temperature-depth profiles were measured using a Sea&Sun CTM2049 CTD during RV ALKOR cruise AL639. The CTD was equipped with duplicate sensors for temperature, conductivity and oxygen. The oxygen sensor (galvanic oxygen micro-sensor (AMT)) was exchanged in the beginning of the year. All other sensors were calibrated in March 2024. The sensors are used throughout the year and no post-cruise calibration is applied. Data were connected to the station book of the specific cruise as available in the DSHIP database. This dataset presents conductivity–temperature–depth (CTD) profiles collected during the research cruise. The data were processed using a custom Python workflow designed to summarize, standardize, and prepare CTD measurements for publication. Raw sensor output files (.TOB format) were parsed using a dedicated reader that extracts header metadata and harmonizes variable naming conventions across all profiles. Quality control procedures included the removal of non-physical values, treatment of missing or malformed entries, and consistency checks across key variables such as pressure, temperature, conductivity, and derived parameters (e.g., salinity and oxygen). Oxygen values were scaled, and salinity values were corrected according to the respective CTD calibration. Sensor channels were standardized and renamed to ensure compatibility with common data standards. Pressure was linearly interpolated to a uniform 1 dbar grid, and all depth-dependent parameters were interpolated accordingly. Maximum recorded pressure was cross-checked against local bathymetry (elevation); in cases of mismatch, profiles were truncated at the maximum depth of the corresponding location. The workflow further includes visual quality control of oxygen saturation, station locations, and vertical profiles of temperature, salinity, and oxygen.

Continuous thermosalinograph oceanography along RV POLARSTERN cruise track PS126

Raw data acquired by two thermosalinographs (SBE21, SeaBird GmbH) on board RV POLARSTERN were processed to receive a calibrated and validated data set of temperature and salinity during expedition PS126. Data were downloaded from DAVIS SHIP data base (https://dship.awi.de) with a resolution of 1 sec. Both sensors were equipped with an additional external temperature sensor (SBE38, Sea-Bird GmbH). The raw data are converted to temperature and conductivity values using the calibration coefficients from the calibration before deployment. However, data can only be finally processed after replacement and renewed calibration because correction values for the sensor drift can only be obtained by the post cruise calibration. Thermosalinographs on board RV Polarstern are exchanged about once a year and calibration procedures are conducted after every exchange. Salinity was calculated according to the instructions from the Practical Salinity Scale PSS-78 using the obtained internal temperature and conductivity data. Processing and evaluation of the data is outlined in the data processing report found at EPIC repository https://hdl.handle.net/10013/epic.e9b67f8a-dc1e-4f43-b56d-cfddc20d3c63. Processed data are provided as 10min means of salinity and water temperature aligned with position data taken from master track of the respective cruise.

Physical oceanography during HEINCKE cruise HE574

Conductivity-temperature-depth profiles were measured using a Seabird SBE 911plus CTD during RV Heincke cruise HE574 between 12.04.2021 and 17.04.2021. Additional sensors included a WET Labs C-Star transmissometer and a WET Labs ECO-AFL fluorometer. Data were connected to the station book of the specific cruise as available in the DSHIP database. Processing of the data including removal of obvious outliers followed the procedures described in CTD Processing Logbook of RV Heincke (hdl:10013/epic.47427). A detailed report on the CTD data of HE574 is available at https://hdl.handle.net/10013/epic.7e2aff22-0a3b-4945-a6b4-4796811bb77e.

Raw data of physical oceanography during RV HEINCKE cruise HE658

Raw physical oceanography data was acquired by a ship-based Seabird SBE911plus CTD-Rosette system onboard RV HEINCKE. The CTD was equipped with duplicate sensors for temperature (SBE3plus), conductivity (SBE4) and oxygen (SBE43). Additional sensors such as a WET Labs C-Star transmissometer, a WET Labs ECO-AFL fluorometer (FLRTD) and an altimeter (Teledyne Benthos PSA-916) were mounted to the CTD. The data was recorded using pre-cruise calibration coefficients. No correction, post-cruise calibration or quality control was applied. Processed profile data are available via the link below (Other version).

Charakterisierung von Mineralstaub-Deposition mit hoher Zeitauflösung im Hinblick auf Partikelgröße, Zusammensetzung und atmosphärische Alterung an für ein atmosphärisch-ozeanisches Staubbudget relevanten Standorten

Nass- und Trockendeposition sind die wesentlichen Prozesse, die Mineralstaub aus der Atmosphäre entfernen. Teragramm Mineralstaub werden pro Jahr interkontinental verfrachtet. Erreicht Staub weitab von seiner Quelle wieder die Erdoberfläche, kann er erheblichen Einfluss auf Ökosysteme haben. Insbesondere ozeanische Ökosysteme sind in ihrer Bioproduktivität nährstofflimitiert. Diese Nährstoffe können durch Mineralstaub eingetragen werden. Trotz der Bedeutung der Deposition sind Messungen bislang rar, und Staubmodelle, die sich an den wenigen Messungen validieren, zeigen erhebliche Fehler. Hauptsächlich der Mangel an geeigneten Messdaten behindert im Moment das weitergehende Verständnis des Staubzyklus. Fehlende standardisierte Messtechnik zur Trockendepositionsmessung erschwert bislang gute Datenerfassung. Daher wird ein neuer automatisierter Nass- und Trockendepositionssammler entwickelt und charakterisiert. Der Sammler wird mit meteorologisch relevanter Zeitauflösung (Stunden bis Tage) betrieben und damit einen großen Nachteil vergangener Messungen beheben, nämlich eine Zeitauflösung von meist Wochen bis Monaten. Durch den Einsatz automatisierter rasterelektronenmikroskopischer Einzelpartikel-Analyse wird ein bisher unerreichter Daten-Detailreichtum für Partikelgrößen von 700 nm bis 100 mym zur Verfügung stehen, einschließlich Partikelgrößenverteilung, Elementzusammensetzung und Partikel-Mischungszustand. Besondere Aufmerksamkeit wird potentiellen Nährstoffen wie Fe, P, K, Mg und Ca gewidmet. Für ausgewählte Proben wird weiterhin Partikel-Hygroskopizität bestimmt.Nach der Testphase auf der Insel Frioul, Frankreich, während der der Sammler im Vergleich zur dort existierenden Zeitreihe validiert wird, werden drei Instrumente an Stationen in Betrieb genommen, die für Staubeintrag in die relevant Ozeane sind: Sao Vicente, Kap Verde und Barbados im Saharischen Ausfluss so wie Heimaey, Island, im arktischen Staub. In einer zweiten Phase (nach dem vorliegenden Projekt) soll das Netzwerk dann erweitert werden durch New Island, Falkland im südamerikanischen Ausfluss, Amakusa, Japan im asiatischen Ausfluss und die Insel Amsterdam zwischen dem südafrikanischen und dem australischen Ausfluss. Zum ersten Mal werden aus diesem Projekt kontinuierliche Zeitreihen der Nass- und Trockendeposition von Mineralstaub zur Verfügung stehen, die tägliche bzw. Ereignis-basierte Zeitauflösung und zudem Partikel-Größenauflösung bieten. Hieraus werden atmosphärische Schlüsselfaktoren abgeleitet, die zur Deposition führen. Weiterhin wird eine Partitionierung zwischen Nass- und Trockendeposition und ihr Größenverteilung von Nährstoffen - insbesondere P und Fe - untersucht. Partikel-Mischungszustand und Form werden durch ein Mischungsmodell und Bildanalyse bestimmt. Eine öffentliche Datenbank wird bereitgestellt, die z. B. für Modellvalidierung zu Verfügung steht. Es ist geplant, die Stationen nach Ende der DFG-Finanzierungphase weiter zu betreiben.

Physical oceanography during ALKOR cruise AL594

Conductivity-temperature-depth profiles were measured using a ADM-CTD SN MOCNET during RV ALKOR cruise AL594. The CTD was equipped with duplicate sensors for temperature, conductivity and oxygen. The oxygen sensor (galvanic oxygen micro-sensor (AMT)) was exchanged in the beginning of the year. The sensors are used throughout the year and no post-cruise calibration is applied. All other sensors of the CTD are calibrated irregularly. Data were connected to the station book of the specific cruise as available in the DSHIP database. This dataset presents conductivity–temperature–depth (CTD) profiles collected during the research cruise. The data were processed using a custom Python workflow designed to summarize, standardize, and prepare CTD measurements for publication. Raw sensor output files (.TOB format) were parsed using a dedicated reader that extracts header metadata and harmonizes variable naming conventions across all profiles. Quality control procedures included the removal of non-physical values, treatment of missing or malformed entries, and consistency checks across key variables such as pressure, temperature, conductivity, and derived parameters (e.g., salinity and oxygen). Oxygen values were scaled, and salinity values were corrected according to the respective CTD calibration. Sensor channels were standardized and renamed to ensure compatibility with common data standards. Geographic coordinates were converted from degrees and minutes to decimal degrees to improve geospatial usability. Pressure was linearly interpolated to a uniform 1 dbar grid, and all depth-dependent parameters were interpolated accordingly. Maximum recorded pressure was cross-checked against local bathymetry (elevation); in cases of mismatch, profiles were truncated at the maximum depth of the corresponding location. The workflow further includes visual quality control of oxygen saturation, station locations, and vertical profiles of temperature, salinity, and oxygen.

Physical oceanography during RV HEINCKE cruise HE658

Conductivity-temperature-depth profiles were measured using a Seabird SBE 911plus CTD during RV HEINCKE cruise HE658. The CTD was equipped with duplicate sensors for temperature (SBE3plus), conductivity (SBE4) and oxygen (SBE43). Additional sensors such as a WET Labs C-Star transmissometer, a WET Labs ECO-AFL fluorometer and an altimeter (PSA-916 Teledyne (Benthos)) were mounted to the CTD. Temperature, conductivity and oxygen sensors are calibrated by the manufacturer once a year before being mounted in January. They are used throughout the year and no post-cruise or in-situ calibration is applied. All other sensors are calibrated irregularly. Data were connected to the station book of the specific cruise as available in the DSHIP database. Processing of the data including removal of obvious outliers followed the procedures described in CTD Processing Logbook of RV HEINCKE (hdl:10013/epic.47427). The processing report for this dataset is linked below.

1 2 3 4 5 … 172 173 174